Merge and Resample Module - Geometry Page

The Merge and Resample modules Geometry page displays the extents and resolution of the output lattice. To open the Geometry page, click on the Merge or Resample modules in the Network Manager.  In the Property Manager, click on the Geometry tab.

 

This is an example of the information displayed

in the Property Manager on the Geometry

tab for a Merge module.

 

Automatically Set Limits

Check the box next to Calculate from input to have Voxler automatically calculate the extents of the output lattice based on the combined extents of the input lattices.

 

X Limits

The X Limits item displays the limits in the X direction for the function lattice. Enter the X min and X max coordinates. These ranges are the limits of the lattice that is created. The values are in map coordinates. To change the values, highlight the existing value and type the desired minimum or maximum value.

 

Y Limits

The Y Limits item displays the limits in the Y direction for the function lattice. Enter the Y min and Y max coordinates. These ranges are the limits of the lattice that is created. The values are in map coordinates. To change the values, highlight the existing value and type the desired minimum or maximum value.

 

Z Limits

The Z Limits item displays the limits in the Z direction for the function lattice. Enter the Z min and Z max coordinates. These ranges are the limits of the lattice that is created. The values are in map coordinates. To change the values, highlight the existing value and type the desired minimum or maximum value.

 

Resolution

Resolution is the number of nodes created in the lattice. By default, this value is 50 in each direction. Enter the number of nodes ( Nx, Ny, and Nz) on each axis in the lattice. An increase in the number of lattice nodes provides more resolution, but also increases the amount of time needed to create the lattice and to draw output graphics. It also increases the amount of memory needed to display graphics on-screen and to save the graphic to a .VOXB file. To change the resolution, highlight the existing value and type a new value or click the button to increase or decrease the values. Values can be between 1 and 10000.

 

See Also

Merge

Resample

Slice

Connecting Modules

Computational Modules

Introduction to Modules